Our Technology

Measurement technology
designed for precision.

Vibration Correction

< 1 nm Repeatability.
Directly on the Shop Floor.

For decades, the industry rule was clear: ultra-precise White Light Interferometry (WLI) in a production environment is simply impossible. To capture details at the sub-nanometer scale, traditional systems required vibration-free laboratory conditions, massive air-bearing tables, and complex isolation setups. On an actual shop floor, heavy machinery and ambient vibrations would instantly destroy measurement accuracy.

metubiq rewrites the rules of inline metrology.

We have solved what was previously considered unachievable. Our proprietary vibration-correction technology breaks through physical lab constraints by pairing specialized sensor hardware with advanced signal processing.

With this we are able to deliver measurement results with lab qualility.

METUBIQ precise optical measurement on the shop floor

True In-line / In-situ Quality Control

Measure sub-nanometer topographies directly inside your manufacturing line without diverting parts to a quality lab.

Instant Process Insight

Get fast feedback to optimize process parameters, prevent costly scrap, and boost overall yield.

Zero Structural Overhead

Eliminate expensive air-bearing tables, isolation enclosures, and dedicated cleanroom environments.

Uncompromising Robustness

Experience maximum measurement reliability and long-term stability, even under harsh industrial operating conditions.

Influence of Vibrations

How Environmental Vibrations
Corrupt Measurement Data.

White Light Interferometry relies on an extremely precise, linear vertical scan motion to capture light interference patterns at the nanometer scale. To accurately reconstruct surface topographies, the axial movement must remain strictly constant throughout the entire measurement depth.

← In a real manufacturing environment, this linear scan path is continuously disrupted, which is visibly in a "shaky" interference pattern

Environmental vibrations interfere with the precise axial motion required during acquisition. These disturbances affect scan linearity and ultimately compromise the integrity of the measurement data.

Disruption of Scan Linearity

Any unexpected axial displacement—whether from ambient noise or internal drive axis imperfections— distorts the motion profile required for accurate signal evaluation.

Transient Shocks & Mechanical Impacts

Heavy impacts, press strokes, or parts handling cause sudden axial shifts, leading to phase jumps, severe height artifacts, or invalid data stacks.

Broadband Vibration Spectrum

Industrial shop floors create a continuous mix of low-frequency structural oscillations and high-frequency machine noise that traditional passive shielding cannot fully block.

Hidden Measurement Errors

In environments with mild vibrations, measurements often look perfectly fine at first glance— yet they contain subtle, undetected height errors. Traditionally, highly skilled metrology specialists are required to constantly evaluate data integrity.

Measurement Data

Vibrations leave measurable traces.

Environmental vibrations can influence the measurement signal in different ways. The following example illustrate how disturbances affect the acquired data and the resulting surface information. The measured surface topography has significant distortions due to vibrations. But in this case the surface doesn't contain any phase jumps and the error could be easily overseen. The difference between the corrected and uncorrected surface shows the measurement error due to vibrations.

Measurement data before vibration correction

Without Correction

Measurement data affected by environmental vibrations. A sligth waviness on the surface is visible but can easily be overseen.

Measurement data after vibration correction

With Correction

The same measurement after correction for vibration disturbances.

Detailed comparison of vibration influence

Detailed Comparison

The difference between the corrected and uncorrected surfaces show reveals how vibrations can influence the reconstructed surface data.

Comparison of vibration influence on measurement data
Additional sources of error

It's not just the environment.

As mentioned above, White Light Interferometry (WLI) relies heavily on smooth, linear scanning movements and precise hardware execution of the set parameters. However, actual conditions often tell a different story. The graph on the left illustrates a typical real-world scan profile affected by multiple compounding errors.

The dashed blue line represents the ideal 10 µm linear scan profile. The actual measured path (solid blue) clearly shows how far reality deviates from this ideal: the target value of 10 µm is never reached, and the motion of the scan axis exhibits a distinct linearity error (dashed red). On top of that, environmental machine vibrations and three transient shock events interrupt the measurement.

How metubiq solves this

Our system ensures strict scan linearity by actively compensating for axial disturbances directly within the measurement data. This eliminiates enviromental vibration and errors from the measurement systems itself.

Even better: if environmental vibrations ever exceed physically acceptable limits, metubiq automatically detects the anomaly—delivering reliable, specialist-free quality control you can trust blindly.

Process Integration

Unlocking New Horizons for
White Light Interferometry.

By eliminating the requirement for vibration-isolated cleanrooms and heavy optical tables, metubiq liberates sub-nanometer White Light Interferometry from the confines of the metrology lab.

Precision wherever your process demands it.

Our advanced vibration correction bridges the gap between laboratory physics and harsh industrial reality—delivering uncompromised accuracy directly where measurement data is needed.

In Machinery

Directly integrated into processing units and machining centers for immediate tool and surface feedback.

In-Situ

Real-time surface inspection during the manufacturing step—detecting deviations before the part leaves the fixture.

In-Line

Fully automated 100% quality inspection embedded directly into continuous production streams.

Near-Line / At-Line

Instant quality checks positioned right next to production cells without climate or isolation overhead.

Complete Control Without Bottlenecks

Instead of routing samples to a remote lab and waiting for results, metubiq brings sub-nanometer precision straight to the shop floor. This enables automated closed-loop manufacturing, drastic reductions in scrap rates, and seamless 100% quality assurance.